Emergency lighting is a critical part of fire safety. When the mains power fails during a fire, people must still be able to see escape routes, stairs, exits and fire safety equipment. Without it, evacuation becomes slower and more dangerous — especially at night or in buildings with sleeping occupants.
This guide explains the legal requirements, the role of BS 5266, the correct testing and maintenance regime, and what landlords need to know for HMOs and other residential properties.
Under the Regulatory Reform (Fire Safety) Order 2005, the Responsible Person must ensure that escape routes can be used safely. This includes providing adequate illumination if the normal lighting fails.
Emergency lighting is typically required where:
Your Fire Risk Assessment should identify exactly where emergency lighting is needed.
BS 5266 is the British Standard that covers the design, installation, testing and maintenance of emergency lighting systems.
Most competent installers and fire risk assessors use BS 5266 as the benchmark for a suitable system. Following the standard helps demonstrate that you have taken reasonable steps to comply with the Fire Safety Order.
Typical design expectations include:
Emergency lighting must be tested regularly and the results recorded. An untested system is a common finding during Fire Risk Assessments and enforcement visits.
Standard testing regime (based on BS 5266 practice):
| Test Type | Frequency | What is Done | Who Can Do It |
|---|---|---|---|
| Functional / short test | Monthly | Simulate mains failure briefly; check all lights come on | Competent person (can be in-house) |
| Full duration test | Annually | Run the system for its full rated duration (usually 3 hours) | Competent person / qualified contractor |
| Visual / indicator checks | As needed | Check charge indicators and general condition | Responsible person or staff |
Key points:
HMOs are a high priority for emergency lighting because occupants often sleep on the premises and may be less familiar with the layout.
Landlords should:
At Fire Safety Risk Assessment, emergency lighting is assessed as a standard part of every Fire Risk Assessment. We check whether the system is suitable for the premises, whether testing records are in place, and whether any improvements are needed — particularly in HMOs, blocks of flats and commercial properties.
We provide clear, prioritised recommendations so you know exactly what action (if any) is required.
Related reading on our site:
Emergency lighting only protects people if it works when the power fails. Correct design to BS 5266, regular monthly testing, an annual full-duration test, and proper records are the foundation of compliance.
If you manage an HMO, block of flats or commercial premises and are unsure about your emergency lighting, a professional Fire Risk Assessment is the most reliable way to confirm what is required.
Need a Fire Risk Assessment that properly covers emergency lighting? Contact Fire Safety Risk Assessment today for practical, compliant advice.
Trusted Fire Risk Assessment specialists serving Birmingham, Manchester, West Midlands, Warrington, and across the UK. FSRA provides fully compliant Fire Risk Assessments, Asbestos Surveys, and Legionella Risk Assessments to help businesses and landlords protect people, property, and meet legal obligations.